How to work it out
Studs
Studs usually sit at 600 mm centres, plus extra studs at corners, junctions and each side of an opening.
Plates and nogs
A top and bottom plate run the length of the wall, and nogs run between studs. Bottom plates on a concrete slab are H1.2, laid on a damp-proof course (DPC).
Openings
Each window and door needs trimmers, a lintel, and jack studs above and below.
Cutting
Takeoff works out every piece, then cuts them from 4.8 m and 6.0 m lengths to keep waste down.
Worked example
A 6 m external wall, 2.4 m high, on a concrete slab, with a 1200 × 1200 window and an 860 mm door. 90 × 45 SG8, bought in 4.8 m and 6.0 m lengths.
| Item | Qty |
|---|---|
| Framing | |
| 90×45 SG8 H1.26.0 m · Studs, plates, nogs, trimmers · incl. 1 spare | 10 lengths |
| 90×45 SG8 H1.24.8 m · Studs, plates, nogs, trimmers | 2 lengths |
| Lintels | |
| Lintel timber · 2/140×45140×45 SG8 H1.2 · 4.8 m · 4 pieces cut — nail in pairs | 1 lengths |
| Fixings | |
| Framing gun nails90×3.15 galv · pack of 1000 · ≈284 nails | 1 pack |
| Bottom plate fixingsLumberlok Bottom Plate Fixing Anchor, 12 mm bolts or screw anchors · ≈1 every 900 mm + each end + each side of doors | 10 fixings |
| Damp-proof course (DPC)Strip under the bottom plates · width to suit the plate · Full length of every bottom plate on the slab + 10% | 6.6 lm |
This is the list Takeoff produced for that job. Your list will change with your sizes and settings.
Check before you buy
- Stud size, spacing and bracing must suit your wind zone and loads under NZS 3604 — this list counts timber, it doesn’t design the wall.
- H1.2 bottom plates on a slab sit on a damp-proof course (DPC). Fix them down per NZS 3604 — check your plans for the fixing type and spacing.
- Lintels checked against NZS 3604 Table 8.9 for a light roof, 3 m loaded dimension (change under Adjust specs): 1200 mm → 2/140×45, 860 mm → 2/140×45. Lintels under a floor or another wall above need a different table.
What the calculator covers
- Several walls, each with its own openings
- Windows and doors with positions
- External and internal walls
- 90 mm and 140 mm framing
- Slab or timber floor bottom plates
- Lintels sized or checked against NZS 3604 Table 8.9
- Nails and bottom plate fixings
- A drawing of each frame
Questions
How many studs do I need for a wall?
Divide the wall length by the stud spacing (usually 600 mm) and add one, then add extras for corners and openings. The 6 m wall on this page has 17 full-height studs.
Does Takeoff design the wall?
No. It counts timber for the wall you enter and checks roof-only lintels against NZS 3604 Table 8.9. Stud size, spacing and bracing must still suit your wind zone and loads under NZS 3604 or your plans.
What treatment does framing need?
Takeoff lists H1.2 for wall framing, including bottom plates on a slab, which sit on a damp-proof course (DPC). Check your plans.
Get your own list in under a minute
Put in your sizes. Print it, save it as a PDF, email it or take it to your supplier.
Start your wall framing list