Takeoff › Wall framing calculator

Wall framing calculator

Enter each wall with its windows and doors. Takeoff draws the frame and lists the studs, plates, nogs, trimmers and lintels in standard SG8 lengths — cut from what you can actually buy.

Open the wall framing calculator

Free · no sign-up · works on your phone · NZ sizes

How to work it out

Studs

Studs usually sit at 600 mm centres, plus extra studs at corners, junctions and each side of an opening.

Plates and nogs

A top and bottom plate run the length of the wall, and nogs run between studs. Bottom plates on a concrete slab are H1.2, laid on a damp-proof course (DPC).

Openings

Each window and door needs trimmers, a lintel, and jack studs above and below.

Cutting

Takeoff works out every piece, then cuts them from 4.8 m and 6.0 m lengths to keep waste down.

Worked example

A 6 m external wall, 2.4 m high, on a concrete slab, with a 1200 × 1200 window and an 860 mm door. 90 × 45 SG8, bought in 4.8 m and 6.0 m lengths.

ItemQty
Framing
90×45 SG8 H1.26.0 m · Studs, plates, nogs, trimmers · incl. 1 spare10 lengths
90×45 SG8 H1.24.8 m · Studs, plates, nogs, trimmers2 lengths
Lintels
Lintel timber · 2/140×45140×45 SG8 H1.2 · 4.8 m · 4 pieces cut — nail in pairs1 lengths
Fixings
Framing gun nails90×3.15 galv · pack of 1000 · ≈284 nails1 pack
Bottom plate fixingsLumberlok Bottom Plate Fixing Anchor, 12 mm bolts or screw anchors · ≈1 every 900 mm + each end + each side of doors10 fixings
Damp-proof course (DPC)Strip under the bottom plates · width to suit the plate · Full length of every bottom plate on the slab + 10%6.6 lm

This is the list Takeoff produced for that job. Your list will change with your sizes and settings.

Check before you buy

What the calculator covers

Questions

How many studs do I need for a wall?

Divide the wall length by the stud spacing (usually 600 mm) and add one, then add extras for corners and openings. The 6 m wall on this page has 17 full-height studs.

Does Takeoff design the wall?

No. It counts timber for the wall you enter and checks roof-only lintels against NZS 3604 Table 8.9. Stud size, spacing and bracing must still suit your wind zone and loads under NZS 3604 or your plans.

What treatment does framing need?

Takeoff lists H1.2 for wall framing, including bottom plates on a slab, which sit on a damp-proof course (DPC). Check your plans.

Get your own list in under a minute

Put in your sizes. Print it, save it as a PDF, email it or take it to your supplier.

Start your wall framing list