How to work it out
Poles
Small cantilever pole walls usually put about 1.5 times the retained height into the ground, at around 1.2 m centres. Ground conditions matter — get it engineered if in doubt.
Lagging
Count the rows of boards up the wall (height ÷ board cover), then the lengths needed along it, joining on poles.
Concrete
Each pole hole is filled with concrete. Over about 60 bags, ready-mix is usually easier.
Drainage
Every retaining wall needs drainage: a slotted drain coil at the base, clean drainage metal behind, and filter cloth to keep the soil out.
Worked example
A 10 m timber pole wall retaining 1 m of ground, with 150 mm round poles, 200 × 50 lagging and full drainage behind.
| Item | Qty |
|---|---|
| Poles | |
| Retaining poles150 mm SED round H5 · 2.7 m · 1500 mm in the ground · 1.11 m centres | 10 poles |
| Lagging | |
| Lagging boards200×50 H4 Retaining Wall T&G · 3.6 m · 6 rows at 185 mm cover · joins on poles | 19 lengths |
| Fixings | |
| Lagging fixings125 mm galv nails or 150 mm batten screws · pack of 100 · 240 fixings (2 per board per pole) | 3 packs |
| Concrete | |
| Pole concrete – ready-mix20 MPa, poured · 2.33 m³ needed incl. 10% waste | 2.4 m³ |
| Drainage | |
| Slotted drain coil110 mm with filter sock · Along the base of the wall, falling to an outlet | 11 lm |
| Drainage metal20–40 mm clean drainage aggregate · 300 mm wide behind the wall, full height | 3.6 m³ |
| Filter clothNon-woven geotextile · Separates the soil from the drainage metal | 19 m² |
This is the list Takeoff produced for that job. Your list will change with your sizes and settings.
Check before you buy
- Walls retaining no more than 1.5 m of ground, with no extra load above (driveway, building, steep bank), are generally consent-exempt. Any surcharge means a consent is needed.
- If people could fall 1 m or more off the top, a barrier or fence may be needed.
- Pole depth (1.5 × the retained height) and 1.2 m spacing are rules of thumb for small cantilever pole walls. Ground conditions matter — get it engineered if in doubt.
What the calculator covers
- Round poles and lagging sizes
- Pole depth and spacing
- Lagging fixings
- Pole concrete in bags or ready-mix
- Drain coil, drainage metal and filter cloth
Questions
How deep should retaining wall poles go?
A common rule of thumb for small cantilever pole walls is 1.5 times the retained height. For 1 m of ground that is 1.5 m in the ground. Get an engineer if the ground is soft or the wall is carrying extra load.
Do I need a consent for a retaining wall?
Walls retaining no more than 1.5 m of ground, with no extra load above such as a driveway, building or steep bank, are generally exempt. Anything else needs a consent.
Why does a retaining wall need drainage?
Water building up behind the wall pushes on it. Drain coil, drainage metal and filter cloth let the water out.
Get your own list in under a minute
Put in your sizes. Print it, save it as a PDF, email it or take it to your supplier.
Start your retaining walls list