How to work it out

Spouting lengths

Add up each run and buy lengths with the fewest joins. Long runs need an expansion joiner or an expansion outlet.

Brackets

Marley brackets go no more than 500 mm apart (300 mm in high-wind or snow areas), plus one at each end and extra each side of expansion joiners. Each bracket takes at least three stainless screws.

Corners and ends

Count internal and external corners, and a stop end wherever a run finishes without turning a corner.

Downpipes

One outlet per downpipe, plus bends for the offset and clips up the wall.

Worked example

A house with 40 m of spouting on four sides (12, 8, 12 and 8 m), four external corners, two RP80 downpipes and Marley Stormcloud® in white.

ItemQty
Spouting
Marley Stormcloud® spoutingWhite · 5 m · MS1.58 lengths
Spouting bracketsWhite · MS2 · Every 500 mm + each end85 brackets
Spouting joinersWhite · MS5 · Where lengths join5 joiners
Expansion joinersWhite · MS17 · Runs over 16 m or without an expansion outlet · brackets 400 mm each side1 joiners
External corners 90°White · MS64 corners
Expansion outletsWhite · 80 mm · MS8-80 · One per downpipe2 outlets
Downpipe
RP80® downpipeWhite · 3 m lengths · 2 downpipes × ≈2.9 m2 lengths
RP80® bendsWhite · M+F · 2 per offset + 1 at the bottom6 bends
RP80® downpipe clipsWhite · First within 200 mm of the bend, then max 1.2 m apart6 clips
Fixings
Stainless screws6g × 20 mm stainless · pack of 100 · ≈267 screws · 3 per bracket, 2 per downpipe clip (per Marley)3 packs
Marley MCS® solvent cementWhite · ≈31 joints · don’t glue into expansion outlets or joiners1 tins

This is the list Takeoff produced for that job. Your list will change with your sizes and settings.

Check before you buy

What the calculator covers

Questions

How many spouting brackets do I need?

Allow one every 500 mm plus one at each end. The 40 m example on this page needs 85 brackets.

How much fall does spouting need?

Marley asks for at least 5 mm of fall for every 10 m of run towards the outlets. More fall drains and self-cleans better.

How many downpipes do I need?

It depends on the roof area and rainfall for your site. Takeoff lists what you enter — check the Marley guide or your plans for the number.

Get your own list in under a minute

Put in your sizes. Print it, save it as a PDF, email it or take it to your supplier.